Devices > Remote Devices > OPC Weatherford EIE > Event Directory Data Group

Event Directory Data Group

The OPC Weatherford EIE "Event Directory" (EvtDir) data group gets all types of events from the remote device. On the View Data dialog of the "Event Directory" data group, from the Options drop-down menu, select Get selected event cards to read the cards associated with the highlighted event.

Card Method

The Card Method selection on the Device page of the OPC Weatherford EIE lets you choose whether to use function code FC16 (Legacy FC16/16Ext) or function code 25 (Current FC25) for the device. This selection applies to both Dynagraph cards and events.

Legacy (FC16/16Ext)

The Legacy device option has two types of events available:

Event IDs are not available for the legacy card method. An array of event times and reasons is returned when polled. The first event in the array (index 0) is the most recent. The array index is stored in the Event ID field, making the interface consistent with current messages. The value of this field is used to retrieve the associated dynagraph card.

Current (FC25)

The Current card method supports three types of events:

This event log contains more information than the log file obtained using the legacy method. Each event is assigned an immutable event ID. This event ID is used to retrieve all of the associated dynagraph cards.